SECTION 113.2322. How do I demonstrate continuous compliance with the emission limitations and the operating limits?  


Latest version.
  • (a) You must conduct an annual performance test for all of the pollutants in Table 2 in §113.2357 of this title (relating to Tables Relating to Division 5) for each other solid waste incineration unit to determine compliance with the emission limitations. The annual performance test must be conducted using the test methods listed in Table 2 in §113.2357 of this title and the procedures in §113.2318 of this title (relating to How do I conduct the initial and annual performance test?).

    (b) You must continuously monitor carbon monoxide emissions to determine compliance with the carbon monoxide emissions limitation. Twelve-hour rolling average values are used to determine compliance. A 12-hour rolling average value above the carbon monoxide emission limit in Table 2 in §113.2357 of this title constitutes a deviation from the emission limitation.

    (c) You must continuously monitor the operating parameters specified in §113.2315 of this title (relating to What operating limits must I meet and by when?) or established under §113.2316 of this title (relating to What if I do not use a wet scrubber to comply with the emission limitations?). Three-hour rolling average values are used to determine compliance with the operating limits unless a different averaging period is established under §113.2316 of this title. A 3-hour rolling average value (unless a different averaging period is established under §113.2316 of this title) above the established maximum or below the established minimum operating limits constitutes a deviation from the established operating limits. Operating limits do not apply during performance tests.

Source Note: The provisions of this §113.2322 adopted to be effective May 14, 2009, 34 TexReg 2771