SECTION 4.214. Minimum Design and Construction Information  


Latest version.
  • A permit application for on-lease commercial solid oil and gas waste recycling shall include:

    (1) the typical layout and design of receiving, processing, and storage areas and all equipment (e.g., pug mill), tanks, silos, and dikes.

    (2) a description of the type and thickness of liners (e.g., fiberglass, steel concrete), if any, for all tanks, silos, pits, and storage areas/cells;

    (3) a map view and two perpendicular cross-sectional views of typical pits and/or storage areas/cells to be constructed, showing the bottom, sides, and dikes, showing the dimensions of each; and

    (4) a plan to control and manage storm water runoff and to retain wastes during wet weather, including the location and dimensions of dikes and/or storage basins that would collect storm water during a 25-year, 24-hour maximum rainfall event, and all calculations made to determine the required capacity and design.

Source Note: The provisions of this §4.214 adopted to be effective April 15, 2013, 38 TexReg 2334