SECTION 330.333. Leachate Collection System  


Latest version.
  • Leachate-collection and associated leachate-removal systems shall be:

    (1) constructed of materials that are chemically resistant to the leachate expected to be generated;

    (2) of sufficient strength and thickness to prevent collapse under the pressures exerted by overlying wastes, waste cover materials, and by any equipment used at the landfill; and

    (3) designed and operated to function through the scheduled closure and post-closure care period of the landfill considering the following factors:

    (A) estimated rate of leachate removal;

    (B) capacity of sumps;

    (C) pipe material and strength, if used;

    (D) pipe network spacing and grading, if used;

    (E) collection sump materials and strength;

    (F) drainage media specifications and performance; and

    (G) demonstration that pipes and perforations will be resistant to clogging and can be cleaned.

Source Note: The provisions of this §330.333 adopted to be effective March 27, 2006, 31 TexReg 2502