Texas Administrative Code (Last Updated: March 27,2024) |
TITLE 16. ECONOMIC REGULATION |
PART 4. TEXAS DEPARTMENT OF LICENSING AND REGULATION |
CHAPTER 76. WATER WELL DRILLERS AND WATER WELL PUMP INSTALLERS |
SECTION 76.102. Technical Requirements--Standards for Wells Producing Water Injurious to Vegetation, Land or Other Water
Latest version.
-
(a) Wells completed to produce injurious water shall be cased to prevent the mixing of water or constituent zones. (b) The annular space between the casing and the wall of the borehole shall be pressured grouted with cement or bentonite grout to the land surface. Bentonite grout may not be used if a water zone contains chloride water above one thousand five hundred (1,500) parts per million (milligrams per liter) or if hydrocarbons are present. (c) Wells producing injurious water shall be completed in such a manner that will not allow injurious fluids to flow onto the land surface. Source Note: The provisions of this §76.102 adopted to be effective March 1, 2013, 38 TexReg 1142; amended to be effective September 15, 2014, 39 TexReg 7090