SECTION 4.266. Minimum Design and Construction Information  


Latest version.
  • (a) A permit application for off-lease commercial recycling of fluid shall include the layout and design of the facility by including a plat drawn to scale with north arrow to top of the map showing the location and information on the design and size of all receiving, processing, and storage areas and all equipment, tanks, silos, monitor wells, dikes, fences, and access roads.

    (b) A permit application for off-lease commercial recycling of fluid also shall include:

    (1) a description of the type and thickness of liners (e.g., fiberglass, steel concrete), if any, for all tanks, silos, pits, and storage areas/cells;

    (2) for storage areas where tanks and/or liners are not used, credible engineering and/or geologic information demonstrating that tanks or liners are not necessary for the protection of surface and subsurface water;

    (3) a map view and two perpendicular cross-sectional views of pits and/or storage areas/cells to be constructed, showing the bottom, sides, and dikes, showing the dimensions of each; and

    (4) a plan to control and manage storm water runoff and to retain incoming wastes during wet weather, including the location and dimensions of dikes and/or storage basins that would collect storm water from the facility during a 25-year, 24-hour maximum rainfall event, and all calculations made to determine the required capacity and design.

Source Note: The provisions of this §4.266 adopted to be effective April 15, 2013, 38 TexReg 2334